High power transmission devices
components
-
WR1500 or WR1800 waveguides: for RF power transmisson
-
circulator: for protection of the klystron from reflected power
-
magin-T: devide the RF power into two
-
dummy loads: absorb the reflected RF power. Pure water load is used.
-
phase shifter: for adjustment of the path length
-
E-bend, H-bend, bellows:
rectangular waveguide
reference: CERN accelerator school 1992 "high power RF transmission" R.
K. Cooper
Coaxial transmission x
waveguide designation |
inside dimmension (inches) |
H10 mode operation range (MHz) |
cutoff frequency (MHz) |
cutoff wavelength (cm) |
WR1800 |
18*9 |
410-625 |
328 |
91.44 |
WR1500 |
15*7.5 |
490-750 |
393 |
76.2 |
length of waveguides
Layout of waveguids
klystron room: klystron , circulator, 300kW water dummy load, WR1800
waveguid
underground: magic T, 50kW water dummy loads, WR1500 waveguids
underground: phase shifter, E-bend, arc sensor, IR thermometer
tunnel: RF cavities, tuner, 300kW input coupler
last modified on 19 Dec 2001 by Ohshima